The use of residential aerobic septic systems has been fairly limited, in part, because of the widespread use of conventional septic systems, which are relatively inexpensive and easy to maintain. Conventional septic systems are the most common onsite wastewater treatment systems in rural areas.
The basic aerobic septic system, aka aerobic treatment unit (ATU), is a system that provides a suitable oxygen rich environment for organisms that can reduce the organic portion of the waste into carbon dioxide and water in the presence of oxygen.
Aerobic septic systems are similar to conventional septic systems in that they both use natural processes to treat wastewater. But unlike septic (anaerobic) treatment, the aerobic treatment process requires oxygen. Aerobic treatment units, therefore, use a mechanism to inject and circulate air inside the treatment tank.
Because aerobic septic systems use a higher rate process, they are able to achieve superior effluent quality. The effluent can be discharged directly to the surface.
"HOW IT WORKS"
(1) TRASH TANK everything you flush or dispose down your drains. (2) The Aeration Chamber, the heart of this sewage treatment system, introduces oxygen by aeration compressor (6) into the sewage. The aeration mixes the organic materials of the sewage with the bacterial population, allowing the bacteria to attack and reduce the organic materials. Any activated sludge settling in the final clarifier chamber (3) is reintroduced into the aeration chamber by sewage movement in the aeration chamber..
As solids settle in the clarifier, a clear, odorless effluent rises. At this point the effluent passes through the chlorinator (4), which should contain disinfectant tablets or bleach, for final disinfection. The effluent then enters the chlorine contact chamber (5) or holding tank that stores the chlorinated effluent for discharge through sprinklers.
(above) during installation
(above) complete installation
Sprinklers are set on a timer. The effluent is scheduled to spray in the a.m. hours while you are sleeping.
Included is a 2 year repair warranty.
(DEQ REQUIRED)
#6 Aeration compressor
#8 effluent pump
These are your two mechanical parts.